<rp id="hmzm3"></rp>
<rp id="hmzm3"></rp>

  • <em id="hmzm3"><acronym id="hmzm3"></acronym></em>
  • <rp id="hmzm3"></rp>
    <th id="hmzm3"></th>

    <dd id="hmzm3"></dd>
  • Gold-life micropump development and production center

    Homepage
    Favorite

    | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

     micro-pump, vacuum-class -95, pressure 800kpa.
    SSelect micro-pump
     

     GPMPA Series of DC micro-Pump oil-less Piston High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GPMPA-1/2

    12/24

    0.48/0.28

    300-360

    -75

    4

    214

    35×52×80

    Show

    GPMPA-3/4 12/24

    0.38/0.18

    180 -58 3.5 210

    35×52×80

      Ibid
    GPMPA-5/6 12/24

    0.38/0.18

    110 -48 2.5 210

    35×52×80

      Ibid

    GPMPB Series of DC micro-pump oil-less Piston( High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

     

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPB-1/2

    12/24

    0.48/0.25

    230-200

    65

    5.5

    212

    35×52×80

    Show

    Ibid

    GPMPB-3/4

    12/24

    0.48/0.25

    230-200

    65

    5.5

    212

    35×52×80

      Ibid
    GPMPB-5/6 12/24

    0.48/0.25

    140 50 3.5 212

    35×52×80

      Ibid

    GPMPCSeries of DC micro-pump oil-free piston( High-performance pump, you can load continuous operation, to overcome the shortcomings of the diaphragm pump can be used for gas sampling.)

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPC-1/2

    12/24

    0.58/0.30

    --

    -80

    11

    214

    35×52×80

    Show

    Ibid

    GPMPC-3/4 12/24

    0.58/0.30

    -- -65 9

    214

    35×52×80

      Ibid

     

    GPMPC-5/6 12/24 0.58/0.30 140 -60 6 214

    35×52×80

      Ibid

    GPMPD  Series of DC micro-pump oil-free piston---Pressure: 400kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPD-1/2

    12/24

    0.40/0.20

    >300

    -75

    6

    293

    35×52×105

    Show

    GPMPD-3/4

    12/24

    0.38/0.20

    >200

    -60

    4.5

    293

    35×52×105

      Ibid

    GPMPD-5/6

    12/24

    0.38/0.18

    >150

    -50

    3

    293

    35×52×105

      Ibid

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPE-1/2

    12/24

    0.38/0.20

    >400

    -80

    8

    293

    35×52×105

    Show

    Ibid

    GPMPE-3/4

    12/24

    0.38/0.20

    >250

    -60

    5

    293

    35×52×105

    Show

    Ibid

    GPMPE-5/6

     

    12/24

    0.38/0.18

    >150

    -50

    3

    293

    35×52×105

    Show

    Ibid

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPF-1/2

    12/24

    0.40/0.20

    --

    -80

    13

    293

    35×52×105

    Show

    Ibid

    GPMPF-3/4

    12/24

    0.46/0.20

    >200

    -65

    10

    293

    35×52×105

    Show

    Ibid

    GPMPF-5/6

    12/24

    0.34/0.18

    >150

    -55

    6

    293

    35×52×105

    Show

    Ibid

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPG-1/2

    12/24

    0.38/0.20

    ≈490

    -80

    7.0

    483

    40×58×120

    Show

    GPMPG-3/4

    12/24

    0.38/0.20

    400-450

    -75

    5

    483

    40×58×120

    Show

    Ibid

                       

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GPMPH-1/2

    12/24

    0.48/0.25

    ≈450

    -78

    10

    483

    40×58×120

    Show

    Ibid

    GPMPH-3/4

    12/24

    0.48/0.25

    400

    -75

    8

    483

    40×58×120

    Show

    Ibid

                       

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GPMPI-1/2

    12/24

    0.48/0.25

    >400

    -80

    15

    483

    40×58×120

    Show

    Ibid

     

    GPMPI-3/4

    12/24

    0.48/0.25

    380

    -75

    12

    483

    40×58×120

    Show

    Ibid

                       

    GPMPE Series of DC micro-pump oil-free piston---Pressure: 500kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GPMPJ-1/2 12/24 1.0/0.5 〉380 -80 25 650 58×95×144

    Show

    GPMPJ-1/2 12/24 1.0/0.5 〉260 -70 18 650 58×95×144

    Show

    Ibid

     
                     

    Ibid

    GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GDPMPA-1/2

    12/24

    0.48/0.20

    -- -90 5, and:7

    355

    35×52×127

     

    GDPMPA-3/4

    12/24

    0.48/0.20

    600-700 -82 4.7,and:6

    355

    35×52×127

     

    Ibid

     
    Other parameters Customized       Customized  

    35×52×127

     

    Ibid

    GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GDPMPB-1/2

    12/24

    0.85/0.50

    -- -93 8,and:12

    355

    35×52×127

     

    Ibid

     

    GDPMPB-3/4

    12/24

    0.85/0.50

    -- -89 7,and:10

    355

    35×52×127

     

    Ibid

    GDPMPB-5/6

    12/24

      -- -80 5,and:8   35×52×127  

    Ibid

     

    GDPMPA Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:600kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GDPMPC-1/2

    12/24

    0.90/0.60

    -- -93 13,and:19

    355

    35×52×122

     

    Ibid

     

    GDPMPC-3/4

    12/24

    0.90/0.60

    -- -85 11,and:17

    355

    35×52×122

     

    Ibid

    GDPMPC-5/6

    12/24

    0.90/0.60 -- -70 9,and:15

    355

    35×52×127  

    Ibid

    GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

    GDPMPC-1/2

    12/24

    0.90/0.60

    -- -93 13,and:19

    355

    35×52×122

     

    GDPMPC-3/4

    12/24

    0.90/0.60

    -- -85 11,and:17

    355

    35×52×122

     

    Ibid

     
    GDPMPC-5/6

    12/24

    0.90/0.60 -- -70 9,and:15

    355

    35×52×127  

    Ibid

    GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    Power

    (W)

    Pressure

    (kPa)

     Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GDPMPE-1/2

    12/24 1.0/0.6 -- -93 12and:16 565 40×58×157  

    Ibid

     

    GDPMPE-1/2

    12/24 1.0/0.6 -- -82 8,and:12 565 40×58×157    

    GDPMPD  Series of DC micro-pump oil-free piston Vacum:-80 to -95kPa;Pressure:800kPa.

    High-performance pump that can run under load, to overcome the shortcomings of the diaphragm pump can be used to suppress the system.

    Name and model

    Voltage

    (V)

    No-load Current

    (A)

    Pressure

    (kPa)

    Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GDPMPF-1/2

    12/24 1.0/0.6 -- -93 14,and:20 565 40×58×157  

    Ibid

    GDPMPF-1/2 12/24 1.0/0.6 -- -82 12,and:18 565 40×58×157  

    Ibid

    GPMPAC Series of AC micro-pump oil-free piston Vacum:-80 Pressure:800kPa.The need to provide users with high vacuum, the pump is portable and can plug directly into 220 power. Is a good helper for scientific research and laboratory

    Name and model

    Voltage

    (V)

    Power

    (W)

    Pressure

    (kPa)

     Vacum(kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Detailed Structure

    Show

     

    GPMPAC

    AC220

    1/6

    600

    -80

    23

    2.4

    200×135×170

     

                       
                       

    GDPMPAC Series AC miniature oil-free piston pump --- vacuum:-80kPa need to provide users with high-voltage vacuum, the pump is portable, can be directly inserted 220 electricity. Is a good helper for research and laboratory

    GDPMPAC

    AC220

    1/3

    --

    -80

    35

    5

    320×135×170

     
                       
    Categories