<rp id="hmzm3"></rp>
<rp id="hmzm3"></rp>

  • <em id="hmzm3"><acronym id="hmzm3"></acronym></em>
  • <rp id="hmzm3"></rp>
    <th id="hmzm3"></th>

    <dd id="hmzm3"></dd>
  • Gold-life micropump development and production center

    Homepage
    Favorite

    | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

    Select micro-pump

    pressure unit conversion table

    GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

    Name and model

    Voltage

    (V)

    No-load Current

    (mA)

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    (mL/min)

    Weight

    (g)

    Pump Size

    Detailed Structure of the show

    reference Appearance

    GminiPA-1

    3.5

    30-50

    35

    -25

    800

    16

    162431

    >>here

    GminiPA-2

    3.5

    30-40

    35

    -20

    300

    16

    162431

    >>here

    Ibid

    pressure unit conversion table

    GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

    Name and model

    Voltage

    (V)

    No-load Current

    (mA)

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    (mL/min)

    Weight

    (g)

    Pump Size

    Installation instructions

    Detailed Structure of the show

    reference Appearance

    GminiPB-1

    3.5

    100

    35

    -25

    800

    28

    162441

    >>here

    GminiPB-2

    3.5

    100

    35

    -20

    300

    28

    162441

    >>here

    Ibid

    GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

    Name and model

    Voltage

    (V)

    No-load Current

    (mA)

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Installation instructions

    Structure of the show

    reference Figure

    GMPA-1

    1.5-5

    test:4V

    40-100

    50

    20-30

    0.3-1.5

    35

    402336

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GMPA-2

    2.0-5

    test:4V

    30-100

    50

    30-40

    0.5-2.0

    35

    402336

    Ibid

    Ibid

    GMPA-3

    3-6

    40-70

    50

    20-30

    0.5-1.5

    35

    402336

    Ibid

    Ibid

    GMPA-4

    3-6

    50-90

    50

    30-40

    0.5-1.8

    35

    402336

    Ibid

    Ibid

    GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

    Name and model

    Voltage

    (V)

    No-load Current

    (mA)

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Installation instructions

    Structure of the show

    reference Figure

    GMPC-1/2/3

    6/9/12

    <200/120/90

    >100

    50-65

    2.5-3

    45

    502231

    Structure>>here

    flow-load diagram

    voltage-flow chart

    GMPC-4/5/6

    6/9/12

    <150/110/80

    >80

    50-55

    2.0-2.5

    45

    502231 ibid

    ibid

    GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

    Name and model

    Voltage

    (V)

    No-load Current

    (mA)

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    (L/min)

    Weight

    (g)

    Pump Size

    Installation instructions

    Structure of the show

    reference Figure

    GMPD-1/2/3

    6/12/24

    <230/130/80

    60-100

    60

    3-8

    82

    3544.556.5

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GMPD-4/5/6

    6/12/24

    <200/100/60

    60-100

    50

    3-7

    82

    3544.556.5 ibid

    ibid

    Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

    GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

    Name and model

    Voltage

    (V)

    No-load Current

    mA

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GMPE-1/2

    12/24

    <180/90

    60

    50-55

    3-6

    149

    33543.572

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GMPE-3/4/-

    12/24 -20-40 Custom 3L4L5L 149 3543.572

    Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

    GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GMPF25-1/2

    12/24 0.6/.3 >100 -70 25 480 8656.5126

    Structure>>here

    GMPF15-3/4

    12/24 0.6/0.3 >60 -50 18 480 8656.5126

    Structure>>here

    GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GMPG-1/2

    6-12/24

    <0.450

    100

    20-50

    36

    620

    8670126

    Structure>>here

    GMPG-3/4

    6-9/24

    <0.550

    100

    20-50

    36

    620

    8670126

    ibid

    GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPB-1/2

    6/12

    <0.25/0.135

    100

    series260

    -45-55

    series vacum

     -85

    single:22

    dual:2.8

    55

    244749

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GDMPB-3/4

    6/12

    <0.25/0.135

    100

    series260

    50-65

    single:2.52

    dual:3.8

    55

    244749

    ibid

    GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPC-1/2

    12/24

    <0.135/0.08

    100

    series260

    -45-55

    series vacum

    -75

    single

    22L/min

    dual

    2.8L/min

    75

    244751

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GDMPC-3/4

    12/24

    <0.135/0.08

    series

    260

    -50-65

    series vacum

    -80

    single:2.52

    dual:3.8

    5

    244751

    ibid

    GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

    Name and model

    Voltage

    (V)

    No-load Current

    mA

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPD-1/2

    12/24

    <200

    /135

    100

    -40-50

    series vacum

    -75

    single:72

    dual:10

    107

    354855.5

    GDMPD-3/4

    12/24

    <240

    /135

    100

    -40-60

    series vacum

    -80

    single:82

    dual:11

    107

    354855.5

    GDMPD-5/6

    12/24

    <180

    /115

    100

    -35-45

    single:52

    dual:8

    107

    354855.5

    GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

    Name and model

    Voltage

    (V)

    No-load Current

    mA

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPE-1/2

    12/24

    <180/100

    100

    -40-50

    series vacum

    -75

    single:62

    dual:10

    175

    354871.5

    flow-load diagram

    voltage-flow chart

    Structure>>here

    GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPF(40)-1/2

    12/24

    0.80

    100

    20-60

    single:282

    dual:40

    618

    1056.5126

    voltage-flow chart

    Structure>>here

    GDMPF(25)-3/4

    12/24

    0.70

    100

    20-60

    single:202,

    dual:25

    663

    1056.5126

    ibid

    GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GDMPG(50)-1/2

    6-12/24

    <1.0

    60

    20-50

    single:352

    dual:50

    759

    11070126

    Structure>>here

    GDMPG(35)-3/4

    6-12/24

    <1.0

    -50-60

    20-50

    single:252

    dual:50

    759

    11070126

    Structure>>here

    GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

    Name and model

    Voltage

    (V)

    No-load Current

    A

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

    Structure>>here

    GFMPE-3/4

    12/24

    <0.67/0.35.67

    --

    45

    Four:3-15

    375 4564.5124
    Other Four:1-10 375 4564.5124

    HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

    Name and model

    Voltage

    (V)

    No-load Current

    mA

    Pressure

    (kPa)

    Vacum

    (kPa)

    Intake Flow

    L/min

    Weight(g)

    Pump Size

    Structure of the show

    reference Figure

    HLA-2

    --

    50mL and 100mL two tranches.

    Help

    Categories

     

                               Return Home Page